Summary: This technical bulletin contains information regarding the 24C708AF Videology badging camera. This bulletin also includes instruction for installing the Videology software and camera setup for DNA Fusion.
Download Technical Bulletin (PDF):
https://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.png00Lauren Yorkhttps://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.pngLauren York2019-09-16 15:03:252019-09-16 15:04:42TB 19.15 - Videology Information
Applies To: The Series 3 RSC-2, SSP-D2 (LP), and SSP-LX.
Issue: When replacing or upgrading an applicable board, the position of the Reader Power Select jumper may cause the reader to lose power.
Resolution: Verify that the position of the Reader Power Select jumper is in the correct position. The Reader Power Select jumper is set depending on the voltage (Vdc) requirements of the reader. This technical bulletin will explain how moving the Reader Power Select jumper enables how much power the reader receives. Download Technical Bulletin (PDF):
Summary: This technical bulletin describes the new functionality added to Fusion Web and explains the necessary steps to upgrade an existing system. Download Technical Bulletin (PDF):
https://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.png00Lauren Yorkhttps://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.pngLauren York2019-07-31 09:37:462019-07-31 09:39:15TB 19.12 - Fusion Web Changes for ASSA Access Levels
Topic: Creating ASSA hardware filters in DNA Fusion.
Applies To: ASSA ABLOY Hardware
Summary: This technical bulletin explains filtering support for ASSA hardware and access levels in DNA Fusion. Creating a new hardware filter in DNA Fusion allows the ASSA hardware and access levels to be grouped into a filter. DNA Fusion filters determine the operator’s view in the Hardware Browser’s access levels. This filter can then be applied to an operator or workstation. This bulletin describes the process of creating an ASSA filter in DNA Fusion. Download Technical Bulletin (PDF):
https://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.png00Lauren Yorkhttps://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.pngLauren York2019-07-16 13:22:072019-07-16 13:22:34TB 19.11 - ASSA Filtering in DNA Fusion
Topic: Setting the Power Reader Select jumper to the appropriate configuration to allow power to the reader.
Summary: The Series 3 access control panel’s jumper setting is utilized differently than previous series boards. By default, the Power Reader Select jumper is in the 12V position. If powering a 12-volt reader, the Power Reader Select jumper must be set to pass through (PASS/PT). This allows power to pass-through the input voltage of the control panel. Readers that require different voltage or have high current requirements should be powered separately.
Download Technical Bulletin (PDF):
https://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.png00Lauren Yorkhttps://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.pngLauren York2019-07-16 12:46:132019-07-16 12:49:12TB 19.13 - Power to the Reader on Series 3 Panels
Topic: Requesting and downloading a DNA Fusion demo license.
Summary: This technical bulletin will explain the process of requesting a DNA Fusion demo License through Open Options. This bulletin will also cover the downloading process and where to find additional information.
Download Technical Bulletin (PDF):
https://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.png00Lauren Yorkhttps://www.ooaccess.com/wp-content/uploads/2019/01/OOLogo_H-01-2-300x100.pngLauren York2019-06-20 09:05:322019-06-20 09:05:32TB 19.10 - Requesting a DNA Fusion Demo License
Issue: SSP-LX controllers running firmware version 1.22.9 are having trouble directly upgrading the controller’s firmware to version 1.26 or higher.
Solution: Download and run two separate installers on the DNA Fusion server to upgrade the firmware in increments. The installer links are included in this technical bulletin. Upgrade the SSP-LX controller to firmware version 1.25.7.087 after downloading the first installer. Then download the second installer to enable upgrades to version 1.26 or later versions.
Summary: SSP-LX controllers running on the firmware version 1.22.9 are having trouble directly upgrading to firmware version 1.26 or higher. Upgrade the SSP-LX controller to firmware version 1.25.7.0687 and then the controller’s firmware can be upgraded to version 1.26 or higher. In addition to the incremental firmware updates, two installers are required to complete the upgrade.
Topic: SSP controllers periodically losing network connection and going offline
Applies to: SSP Controllers (All Mercury EP Series)
Summary: Mercury discovered that gratuitous ARP requests are causing connection issues for some SSP controllers (Mercury EP series controllers). Updating the controller’s firmware to version 1.274 corrects the issue and only sends ARP request if the controller detects a change in the Ethernet link state.
Resolution: Update the firmware in the SSP Controller with version 1.274. Download the full Technical Bulletin for instructions on how to download firmware to controllers.
Topic: Unknown Event Received at Driver displays when using Mercury hardware based elevator control
Applies to: Elevator control using Mercury hardware and DNA Fusion
Summary: The “Unknown Event received at Driver” event is displayed when an elevator is being accessed. The event does not indicate an error or affect functionality, however disabling the event from appearing on the Events Grid is an option until version 7.6 is available. In the interim, the event can be disabled from displaying in the Event Grid. Additional elevator access information will be populated with the release of DNA Fusion 7.6
Resolution: Download the full technical bulletin below for instruction on how to disable the event from the Event logging Editor in DNA Fusion. This will prevent the event description from showing up on the Event Grid. Once DNA Fusion 7.6 has been released, Open Options recommends upgrading the system and re-enabling the event.